Transponder
7.13 SIMATIC RF640T Gen 2
Figure 7-32
7.13.3.6
Use of the transponder in hazardous areas for dusts
The equipment is suitable for dusts whose ignition temperatures for a dust layer of 5 mm are
higher than 210 °C (smoldering temperature). The ignition temperature specified here
according to IEC 60079-0: 2011 for ignition protection type ib in this case references the
smoldering temperature of a layer of combustible flyings (ib IIIA) or alternatively non-
conductive dusts (ib IIIB).
Temperature class delineation for dusts
Ignitions of dust-air mixtures
When using the RF640T transponder, check to ensure that the temperature values are
complied with in connection with the requirements of the application area.
Non-compliance with the permitted temperature ranges while using the transponder can
lead to ignitions of dust-air mixtures.
Temperature class assignment for dusts and a radiated power less than 100 mW ERP
If the radiated power of an antenna radiating into the hazardous area or located in the
hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the
value 100 mW, the temperature class assignment is as follows:
Ambient temperature range
-25 °C ≤ Ta ≤ +85 ℃
372
Maximum permitted ambient temperature depending on the radiated power
WARNING
Temperature value
T94 °C
System Manual, 10/2016, J31069-D0171-U001-A19-7618