Download Print this page

Siemens SIMATIC RF600 Series System Manual page 356

Simatic ident
Hide thumbs Also See for SIMATIC RF600 Series:

Advertisement

Transponder
7.11 SIMATIC RF625T
Permitted ambient conditions
Ambient temperature
Distance from metal
Degree of protection
Resistance to mechanical stress
Shock according to DIN EN 60721-3-7, Class 7
M3
Vibration to EN 60068-2-6
Design, dimensions and weight
Dimensions (∅ × D)
Weight
Standards, specifications, approvals
MTBF
Reduction of range to about 70% at the band limits 902 MHz or 928 MHz; acquisition is
1)
guaranteed at 915 MHz due to frequency hopping procedure.
Mounting on a flat metal surface with a diameter of at least 150 mm and at room
2)
temperature. The information relates to the maximum read range. You will find more
information on ranges in the section "Minimum distances and maximum ranges (Page 293)".
When these minimum distances are not achieved, there is a reduction in the maximum
possible read and write distances of the transponder.
The values for shock and vibration are maximum values and must not be applied
3)
continuously.
356
In operation, during write/read access
In operation, outside write/read access
During transportation and storage
6GT2810-2EE0x
-25 to +85 °C
-40 to +125 °C
-40...+125 ℃
Suitable for direct attachment to metal
IP68 / IPx9K
Torsion and bending stress is not permitted
100 g
3)
50 g
3)
30 × 8 mm
6 g
1141 years
System Manual, 10/2016, J31069-D0171-U001-A19-7618
SIMATIC RF600