Download Print this page

Siemens SIMATIC RF600 Series System Manual page 341

Simatic ident
Hide thumbs Also See for SIMATIC RF600 Series:

Advertisement

Table 7- 27
Carrier material
Metal plate at least 300 x 300 mm
The use of spacers on metallic surfaces is recommended.
On rectangular carrier plates, the range depends on the mounting orientation of the
transponder A 90° rotation of the transponder about the axis of symmetry may result in
greater ranges.
You will find more detailed information on the range in the section "Minimum distances and
maximum ranges (Page 293)".
7.9.3.2
Range when mounted on non-metallic carrier materials
The transponder is generally designed for mounting on non-metallic objects which provide
the conditions for the maximum reading ranges
Table 7- 28
Carrier material
Transponder on wooden carrier
(dry, degree of moisture < 15%)
Transponder on plastic carrier
Transponder on glass
Transponder on plastic mineral water bottle
The maximum range of 100% is achieved by mounting the transponder in a free space with
low reflections on a metal-free carrier with a diameter of at least 300 mm.
You will find more detailed information on the range in the section "Minimum distances and
maximum ranges (Page 293)".
7.9.4
Technical specifications
Table 7- 29
Product type designation
Radio frequencies
Operating frequency
SIMATIC RF600
System Manual, 10/2016, J31069-D0171-U001-A19-7618
Range with flat metallic carriers with spacers
Range with non-metallic carriers
Technical specifications of the transponder SIMATIC RF620T
ETSI
FCC
Range
typically 87%
Range
typically 75 %
typically 75 %
typically 75 %
typically 15 %
SIMATIC RF620T
865 to 868 MHz
902 to 928 MHz
Transponder
7.9 SIMATIC RF620T
6GT2810-2HC81
341