Antennas
6.7 RF680A antenna
Interfaces
Plug connection
Mechanical specifications
Material
Color
Tightening torque (at room temperature)
Permitted ambient conditions
Ambient temperature
Degree of protection
Shock resistant to EN 60068-2-27
Vibration to EN 60068-2-6
Design, dimensions and weight
Dimensions (H x W x D)
Weight
Status display
Standards, specifications, approvals
Proof of suitability
MTBF
The values differ for different dimensions/materials of the mounting surface.
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
282
During operation
During transportation and storage
RTNC coupling (for connection of the anten-
na cable)
Pocan
Pastel turquoise
≤ 2 Nm
-25 to +75 °C
-40 to +85 °C
IP65
30 g
2)
10 g
2)
198 x 198 x 60 mm
690 g
1 LED
CE (according to R&TTE), FCC (Title 47, Part
15.247), cULus
218 years
System Manual, 10/2016, J31069-D0171-U001-A19-7618
6GT2812-2GB08