CONFIGURATOR PROGRAM
The configurator program is used to configure the ACE drives as a Single or a
Dual drive system. It is important that you do not change any of the other
parameters. After using the Configurator program ("A" option), use the "U"
option to update the EEPROM (to save the new configuration). If you do not
update the EEPROM the new configuration will not be saved and the previous
configuration will be used.
File# Program
2
GESCSI CONFIGURATOR
3
GESCSI FORMATTER
4
GESCSI INITIALIZER
5
MV7800 MICROCODE LOADER REV. xx
File Number? 2<CR>
The purpose of the configurator program is to allow you to tailor the GESCSI controller to your particular
environment. The GESCSI controller includes an electrically erasable prom (EEPROM) which contains certain
facts. This program lets you list the cur rent facts, modify those that you want changed, and
record the new facts onto the EEPROM.
The HELP command on the main menu provides information both on what to do and how to do it. If this is the
first time you have run this program, you might want to start by selecting HELP.
You can get an explanation of any question the program asks, by responding to that question with an H.
What is the present setting of the device code (in octal) ?24<CR>
Enter command (? to see choices): ?<CR>
COMMAND MENU
A - Change ALL facts
B - BMC priority
D - Describe/Edit any or all Disk drives
F - Throttle burst rate
G - Break count
M - Unit for Microcode
H - HELP - Operations
W - HELP - What To Do
L - LIST all configuration facts
N - START logging to printer
O - STOP logging to printer
U - Update EEPROM
Q - Quit the program
Enter command (? to see choices):