SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Hardware Description
Function/
H801SPUA
Specificatio
n
Ethernet
Supports upstream
upstream
transmission and
transmission
cascading. The
and
network role can only
cascading
be configured based
on board.
You need to run the
service-port
command to create
an Ethernet service
flow to add the
upstream or
cascading port into a
VLAN. The port
vlan command is not
supported in the
H801SPUA board.
If multiple upstream
ports are added into a
protection group,
these ports must be
added into an
aggregation group. In
this way, you only
need to create a
service flow to add
the master port of the
protection group into
the VLAN so that all
the member ports of
the protection group
will be added into the
VLAN.
Ethernet link
Support intra-board
aggregation
link aggregation and
inter-board link
aggregation
Packet
Identifying and
capture
capturing DHCP and
PPPoE packets with
3 tags
(V800R013C00 and
later versions)
Issue 24 (2018-07-30)
H801SPUC
Supports upstream
transmission and
cascading. The network
role can only be configured
based on board.
You need to run the
service-port command to
create an Ethernet service
flow to add the upstream or
cascading port into a
VLAN. The port vlan
command is not supported
in the H801SPUC board.
If multiple upstream ports
are added into a protection
group, these ports must be
added into an aggregation
group. In this way, you
only need to create a
service flow to add the
master port of the
protection group into the
VLAN so that all the
member ports of the
protection group will be
added into the VLAN.
Support intra-board link
aggregation and inter-board
link aggregation
Identifying and capturing
DHCP and PPPoE packets
with 3 tags
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
H801SPUF
Supports upstream transmission and
cascading. The network role can only be
configured based on board.
l The Layer 3 forwarding mode
supports only the upstream role.
l The Layer 2 forwarding mode
supports both the upstream and
cascade roles.
You need to run the port vlan command
to add the upstream or cascading port
into the VLAN.
Support intra-board link aggregation and
inter-board link aggregation
Identifying and capturing DHCP and
PPPoE packets with 3 tags