Huawei SmartAX MA5600T Hardware Description page 936

Multiservice access module
Hide thumbs Also See for SmartAX MA5600T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Hardware Description
DIP Switches of the Environment Monitoring Board
The I-type DC PDU uses the ESCA environment monitoring board, which provides two sets
of DIP switches S5 and S6.
Figure 6-7 Layout of the DIP switches of the I-type DC PDU
Table 6-6
Table 6-6 Settings of S5 and S6
DIP Switch
S5-1
S5-2
S5-3
S5-4
S6-1
S6-2
S6-3
S6-4
S6-5
S6-6
S6-7
Issue 24 (2018-07-30)
Figure 6-7
ON
S6
H801ESCA
describes the settings of S5 and S6.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
shows the layout of the DIP switches.
S5
Indication
S5 is used to set the external
sensors of JTA1-JTA4 to be
the voltage type or current
type.
l ON: The external sensors
are of the voltage type.
l OFF: The external
sensors are of the current
type.
S6-1 to S6-5 are used to set
the mapping subnode
addresses of system
configuration to ensure
normal communication.
l ON: The address bit is 0.
l OFF: The address bit is
1.
Reserved
Reserved
6 Electromechanical Device
ON
Default Settings
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON