Troubleshooting

8. Troubleshooting
DANGER
• Make sure to turn off the power and other switches of all
any actions for correcting an error.
*: Means this product, the distribution box and other related devices (jigs, robots, etc.)
• As for the inside inspection, make it at least 5 minutes after turning the power off in consideration of
electric discharge from a capacitor.
CAUTION
Notice
Do not turn the power on with the top panel and/or side panel of this product removed.
The electromagnetic force may cause troubles (deformation, mechanical contact, etc.) to the inside devices and parts,
and may break them and/or affect their functions and performance.

8.1 Error codes and messages

• This product is designed to indicate an error status on
the front panel (See the following figure) as shown in the
following table when an error occurs and it can be self-
examined.
E r r
Code
E r r
-01
EmergencyStop
E r r
-02
Sec. OverCurrent
E r r
-03
Temp. Over Error
E r r
-04
Pri. OverVoltage
E r r
-05
Pri. Low Voltage
46
Touching the current-carrying parts may cause a fatal electric shock or
burn injury.
To prevent a physical accident, such as an electric shock, burn injury, etc., make sure
to observe the followings.
• When the power switch is turned off automatically, contact sales distributor or Pana-
sonic representatives without turning it on again.
• The power switch uses a non-fuse circuit breaker. If over-current occurs for some
reasons, the power is turned off automatically (tripping). Do not turn it on again.
• (It is dangerous to turn the power on again without removing the cause of such over-
current.)
Message
An emergency stop signal was input from external equipment connected to
the jig terminal.
• Turn off the power switch of this product, remove the causes of the emergency
stop signal of the external equipment, and then turn the power on.
It may be failure of this product.
Please contact sales distributor or Panasonic representative.
The temperature inside this product has been increased.
• Do not turn the power off until the temperature inside this product is reduced.
(When the inside is cooled down, such error indication disappears automati-
cally.)
• Remove the causes of such temperature increase (excessive usage ratio, the
presence of foreign substances near the side ventilator and/or the rear air inlet,
etc.).
The input voltage has exceeded the permissible limit.
• Turn off the power of this product, set the input voltage to the rated voltage plus
10% or less, and then turn it on again.
The input voltage is lower than the permissible limit.
• Turn off the power of this product, set the input voltage to the rated voltage
minus 10% or more, and then turn it on again.
devices*
• In the case of welding errors that are not covered in the
following table, see "Troubleshooting" table.
Those error code is also indi-
cated on the 7-segment LED on
the PC Board (ZUEP1398)
inside the product.
Remedy
for safety reasons before taking
OMCTT5639E09