Names and Functions
Welding method
MIXTIG
Outputs an AC (standard)
TIG waveform and a DC
TIG waveform alternately.

4.3 Welding conditions

4.3.1 Welding condition setting table

• Items marked with (P) in the following table is applied to
the mode of the pulse "present" (set by "pulse" selection
button).
Crater
Weld-
Pre-flow
ing
time
method
(O)
OFF
DC
ON
(O)
TIG
Repeat
(O)
Spot
(O)
OFF
AC
ON
(O)
TIG
Repeat
(O)
Spot
(O)
OFF
MIX
TIG
ON
(O)
Repeat

4.3.2 About welding conditions

• Pre-flow time
• Initial current
• Up slope
• Welding current
• Down slope
• Crater current
• Post-flow time
• Pulse current
22
Output waveform
Main materials
(Image)
D C
A C
Weld-
Up
Down
Spot
ing cur-
slope
slope
rent
(O)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
Fig.1 In case of DC TIG welding with "Pulse" and "Crater"
Torch switch
operation
Pulse
current
Output current
Welding
current
Shield gas
• Due to the difference in heat input between AC
and DC, neatly wave-patterned bead appearance
is obtained.
• With DC TIG and AC TIG mixed together, good
weld penetration can be achieved.
• Arc with strong convergence is available.
Aluminum
• Suitable for the fillet welding of a thin plate.
Magnesium
• Suitable for vertical and upward welding.
Brass
• Electrode exhaustion is considerably reduced.
• Inserting filler wire during the AC period enables
improvement in working property.
• Setting the MIX TIG frequency to 1 through 2Hz
makes it easier to control the insertion timing of
filler wire.
• In the case of MIX TIG welding, the spot welding is not
available.
Crater
Post-flow
Pulse
time
time
time
current
(O)
(P)
(O)
(O)
(P)
(O)
(O)
(P)
(O)
(O)
(P)
(O)
(O)
(O)
(O)
(O)
ON
OFF
Initial
current
Pre-flow
Up slope
Features
Pulse
AC
Pulse
AC bal-
fre-
fre-
width
ance
quency
quency
(P)
(P)
(P)
(P)
(P)
(P)
(O)
(O)
(P)
(P)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
(O)
ON
OFF
Down slope
Post-flow
OMCTT5639E09
MIX
DC
fre-
ratio
quency
(O)
(O)
(O)
(O)