JOG dial
For welding condition data
Note
Do not turn the jog dial without dis-
cretion. (It may result in the change
of the present set value.)

6.3.7 Storing welding conditions

• Set "FUNCTION" button to "RECORD."
Note
1
The screen on the right
appears on the digital
ammeter.
• Turn the JOG dial and select a program number to be stored.
2
* Numbers starting with "P01" are indicated in order. (Numbers already stored flash.)
<New storage>
• Select a solidly lit (no-flash) number.
• Press the JOG dial, then the "FUNCTION" button automatically returns to "WELD.
<Overwriting>
• Select a number you want to overwrite (the
number flashes).
Note
The screen on the right
appears on the digital
ammeter.
• Turn the JOG dial and have "YES" displayed.
• Press the JOG dial, then the "FUNCTION" button automatically returns to "WELD."
OMCTT5639E09
5
• Set (or check) the welding condition data.
Press a button, which is desired
to be set and confirmed, related
to an indication lamp turned on
Under that condition, turn the
JOG dial and you can change
the set value or that time.
Press the JOG dial to complete
the setting (checking).
JOG dial
"FUNCTION" button
Operation
Indication lamp starts flashing, the name
of that item appears on the LCD display,
and the present set value is indicated on
the set-value display.
As long as that indication lamp is on, the
set value can be changed even during
the welding operation.
*The set welding current can be changed
even when the LCD display is showing
the output voltage screen.
Then, the indication lamp of that item is
turned on, and it becomes impossible to
change the set value by turning the jog
dial.
• Up to 50 welding conditions (P01 to P50) set by custom-
ers can be stored.
Just reproduce your stored welding condition, and you
can proceed with the welding immediately without addi-
tional selection or setup under the stored condition. As
for the note of the condition, refer to section "Appendix:
Welding conditions memorandum."
Note
When the memory locking is on, no information can be
stored.
Set-value display
When solidly lit "P02" is
selected.)
When flashing "P01" is
selected.)
Operation
LCD display
JOG to Sel. No.
Press to Confirm
Overwrite? (Y/N)
JOG to YES/NO