Functions Of Jig Terminal; Connecting With Robot; Applications; Connection - Panasonic YC-300BP2YAF Operating Instructions Manual

Inverter tig welding power source
Table of Contents

Advertisement

5.4.4 Functions of jig terminal

Terminal names
WATER
EMERGENCY
CUR.
DETECTION
PULSE DETEC-
TION

5.5 Connecting with Robot

5.5.1 Applications

• Robot: In case of perform welding operation using Panaso-
nic robots "VR-2 or TA-G2 series" by connecting to the robot
controller.
(For details, see manuals of individual products.)

5.5.2 Connection

Connect the communication cable from a robot to the D-
Sub connector (d)on the rear panel.
Connecting connector
Robot
RS-422(CN22)(d)

5.5.3 Cautions at connecting cables

• To enable the function of communication, make sure
to turn the power off, and then set the DIP switch.
(When not using the function of communication, turn
off the DIP switch #6.)
• Turn the switch (e) on and off from on top of the
orange cover.
OMCTT5639E09
• When the circuit is opened between these terminals, the operation of this product is sus-
pended.(Such suspension results in the stoppage of the welding output, gas supply and gas
inspection.)
• When using the water-cooling torch, connect a signal for reduced-water-level detection, etc.
• To release such suspension, close the circuit between these terminals.
• When the circuit is closed between these terminals, the emergency stop function of this prod-
uct is activated.(Such suspension results in the stoppage of the welding output, gas supply
and gas inspection.)
• To release this emergency top, close the circuit between these terminals after turning the
power switch off, and then turn it on again.
• Even if the power switch is turned on with the circuit between these terminals opened, this
product does not operate. Close the circuit between these terminals, and then turn the power
switch on again. (In other words, turn the power on with the circuit between these terminals
closed.)
• Between these terminals, the normally-open relay contact (contact a) is connected, and it is
closed at all times while output current* is detected.
*: Initial current, welding current (pulse current and base current) and then crater current.
• If there is something to be operated at the jig side while such output current is detected, use
these terminals for such an operation.
• Contact rating: 100VAC 0.5A, 24VDC 2A
• Between these terminals, the normally-open contact (contact a) of a photo MOS relay is con-
nected, and it is closed in synchronization with the pulse output current only.
• Contact rating: 100VAC/DC 0.13A
DIP switch (DSW1)
#6: ON
Function
Note
Keep the signal lines from a jig and/or a robot away from
the welding arc area, the welding torch, the base-mate-
rial-side cable, etc. to prevent troubles caused by incor-
poration of the high frequency wave. And keep the wiring
length within 10m.
a
b
c
(Shown DSW settings are
factory settings at shipment.)
Connection
d
e
29