Rated Specifications

2. Rated Specifications
Rated input voltage
Number of Phase
Rated frequency
Rated input
Efficiency
Idle state power consumption
Rated output current
Rated output voltage
Duty cycle
Output, initial and cra-
(See Note)
ter current
Maximum non-load voltage
Up slope time
Down slope time
Pre-flow time
Post-flow time
(AC TIG) AC frequency
(MIX TIG) MIX frequency
(MIX TIG) DC ratio
Pulse frequency
Pulse width
AC balance adjustable welding method
AC balance
Arc spot time
Control system
Crater control system
High-frequency-wave generating equipment
Communication function
Memory function
Robot interface function
Cooling system
Type of insulation
Dimension (Width: W x Depth: D x Height: H)
Mass
Protection grade
Classification for RF emission tests
List of equivalent
Note
• As arc is stable in the low current range, select an appro-
priate welding condition.
8
DC TIG
Standard
AC TIG
Hard
Soft
MIX TIG
V
Hz
%
W
A
V
%
A
A
A
A
A
V
s
0 - 10 (Increment: 0.1)
s
0 - 10 (Increment: 0.1s)
s
0 - 10 (Increment: 0.1s)
s
0 - 30 (Increment: 0.1s)
Hz
50 - 400 (STD: 70)
Hz
0.5 - 10 (STD: 1.0)(In increment of 0.1Hz.)
%
10 - 90 (STD: 30)(In increments of 5%)
Hz
0.8 - 500
%
%
EP 10 - 50 (Standard: 30)(Increment: 1% )
s
0.1 - 5(Increment: 0.1 s)
IGBT inverter method
Selectable from crater control "ON". "OFF" or "Repeat"
High frequency arc start type
50ch storage and reproduction
Enables communication with Panasonic robot controllers.
mm
kg
• In the case of AC TIG or MIX TIG, when AC frequency is
increased, the rated output current may not be available
due to the voltage drop caused by the impedance (AC
resistance) of the output-side cable. However, this is not
the error of this product.
200
3
50/60
11kVA, 8.8kW
73
62
DC 300, AC 300
DC 22, AC 22
40
4 - 300
10 - 300
20 - 300
10 - 200
10 - 300
DC 65
(50 - 200Hz: In increments of 1Hz)
(200 - 400Hz: In increments of 10Hz)
(0.8 - 9.9Hz: In increments of 0.1Hz)
(10 - 99Hz: In increments of 1Hz)
(100 - 500Hz: In increments of 10Hz)
5 - 95
ACTIG, MIXTIG
RS-232C, RS-422
Forced air-cooling
Class H
380 x 510 x 656
59
IP21S
Class A
-
OMCTT5639E09