3 System Messages
Log No. Type
Class
1824
0
SYSTEM
1825
0
SYSTEM
1826
1
SYSTEM
1827
0
SYSTEM
2049
0
DAU
2050
2
DAU
2051
1
DAU
2056
2
DAU
2057
0
DAU
2058
1
DAU
2059
0
DAU
2064
2
DAU
2065
0
DAU
2066
2
DAU
2067
0
DAU
2068
2
DAU
2069
0
DAU
2070
2
DAU
2071
0
DAU
2072
2
DAU
2073
0
DAU
2074
2
DAU
2075
0
DAU
2076
2
DAU
2077
0
DAU
2078
2
DAU
2079
0
DAU
2306
0
OSCOP
2307
2
OSCOP
2310
2
OSCOP
2311
0
OSCOP
2312
2
OSCOP
284
Description
Common alarm
CPU fault
Data fault
OSCOP P communication aborted. Fault
no.:
Invalid link command requested.
Cmd number:
Measurement system time set
Measurement system time could not be set Hotline
Measurement system started
Unable to start measurement system
Measurement system stopped
Unable to stop measurement system
Recording initiated by manual trigger
Recording not initiated by manual trigger
Recording initiated by OSCOP P trigger
Recording not initiated by OSCOP P trigger Hotline
Recording initiated by external start
Recording not initiated by external start
Recording terminated by external start
Recording not terminated by external start
Recording initiated by network trigger
Recording not terminated by external start
Change to normal mode OK
Fault during change to normal mode
Change to test mode OK
Fault during change to test mode
Change to lock mode OK
Fault during change to lock mode
Login could not be performed
RTC set. New time stamp:
Test mode activated by OSCOP P
Fault during change to test mode by
OSCOP P
Normal mode activated by OSCOP P
Comment
A general common alarm occurred.
For further information on this fault, refer to
detailed log entries.
Several possible reasons: DAU and CPU
software version do not match, firmware
update recommended; CPU hardware error;
contact hotline if necessary
TAR/TPR record cannot be used due to
inconsistent DAU data. Check via external
or manual trigger if recording is now
possible without errors. LED Data fault must
now be off, if not contact hotline.
Communication is terminated if there is no
user activity for 10 minutes. Otherwise,
check the communication link.
Hotline, install SIMEAS R-PMU firmware or
OSCOP P update
Measurement system time was set due to
change of RTC time. Message appears on
device start, too.
Measurement system was started after a
device start or after the termination of the
service mode.
Hotline
Measurement system was stopped when
changing to service mode or due to a
hardware fault.
Hotline
-
Hotline
-
-
Hotline
-
Hotline
-
Hotline
-
Hotline
-
Hotline
SIMEAS R-PMU can change to lock mode
automatically or via control panel or via
OSCOP P. Check further log messages for
details.
Hotline
Hotline, install SIMEAS R-PMU firmware or
OSCOP P update
RTC was set via OSCOP P.
-
Hotline
-
Digital Fault Recorder, SIMEAS R-PMU, Manual
E50417-H1076-C360-A5, Release 10.2012