DANGER
In certain conditions, fuel is extremely flammable
and highly explosive. A fire or explosion from fuel
can burn you and others and can damage property.
• Fill the fuel tank outdoors, in an open area, when
the engine is cold. Wipe up any fuel that spills.
• Never fill the fuel tank inside an enclosed trailer.
• Never smoke when handling fuel, and stay away
from an open flame or where fuel fumes may be
ignited by a spark.
• Store fuel in an approved container and keep it
out of the reach of children. Never buy more
than a 180-day supply of fuel.
• Do not operate machine without entire exhaust
system in place and in proper working condition.
DANGER
In certain conditions during fueling, static
electricity can be released causing a spark which
can ignite the fuel vapors. A fire or explosion from
fuel can burn you and others and can damage
property.
• Always place fuel containers on the ground away
from your vehicle before filling.
• Do not fill fuel containers inside a vehicle or on
a truck or trailer bed because interior carpets
or plastic truck bed liners may insulate the
container and slow the loss of any static charge.
• When practical, remove equipment from the
truck or trailer and refuel the equipment with its
wheels on the ground.
• If this is not possible, then refuel such equipment
on a truck or trailer from a portable container,
rather than from a fuel dispenser nozzle.
• If a fuel dispenser nozzle must be used, keep the
nozzle in contact with the rim of the fuel tank
or container opening at all times until fueling is
complete.
1. Park the machine on a level surface.
2. Using a clean rag, clean the area around the fuel-tank
cap.
3. Remove the cap from the fuel tank
1. Fuel-tank cap
Checking the Level of the
Hydraulic Fluid
Service Interval: Before each use or daily
The reservoir is filled at the factory with approximately 28.4
L (7.5 US gallons) of high-quality hydraulic fluid. Check the
level of the hydraulic fluid before the engine is first started
and daily thereafter.
The recommended replacement fluid is Toro Premium
All Season Hydraulic Fluid (available in 5-gallon pails or
55-gallon drums. See parts catalog or Toro distributor for
part numbers).
Alternative fluids: If the Toro fluid is not available, other
conventional, petroleum-based fluids may be used, provided
that they meet all of the following material properties and
industry specifications. Check with your oil supplier to see
whether the fluid meets these specifications.
Note: Toro will not assume responsibility for damage
caused by improper substitutions, so use only products
from reputable manufacturers who will stand behind their
recommendation.
(Figure
38).
High Viscosity Index/Low Pour Point Antiwear Hydraulic
Fluid, ISO VG 46 Multigrade
29
Figure 38
4. Fill the tank until the level is to the bottom of the filler
neck with fuel.
5. Install the fuel-tank cap tightly after filling the tank.
Note: If possible, fill the fuel tank after each use. This
will minimize possible buildup of condensation inside
the fuel tank.
Material Properties: