4. Technical data

4.1 Operating parameters

BEKOMAT
®
Ambient relative humidity
Maximum operating height
Minimum / maximum operating pressure
Minimum / maximum operating temperature
Average discharge rate
Maximum discharge rate (short-term)
Connection*, Condensate inlet
Connection, condensate discharge
Media
Empty weight
Operating voltage
Power consumption
Degree of protection
Housing class (UL50E)
Overvoltage category (IEC 61010-1)
Degree of pollution (IEC 61010-1)
Recommended cable diameter
Recommended wire cross-section
Recommended shortening of the cable jacket
Recommended stripping length of the cable wires
* The NPT thread version is optional.
16i CO
10 ... 80 %, without condensation
2000 m
2187.23 yd
0.8 ... 16 bar(g)
12 ... 230 psi(g)
+1 ... +60 °C
+34 ... +140 °F
274 l/h
72.38 gal/h
1700 l/h
449.09 gal/h
2 x G3/4, internal, 1 x G1
maximum screw-in depth: 13.5 mm (1/2 in)
1 x G1/2 internal
Condensate, oil-contaminated or oil-free
5.90 kg
13 lbs
24 VDC ±10%
(see type plate)
P <8.0 VA (W)
IP65
TYPE 13
III
3
5 ... 10 mm
0.23 ... 0.33 in
0.25 ... 1 mm²
AWG 18 ... 24
~ 50 mm
~ 1.97 in
~ 6 mm
~ 0.24 in
BEKOMAT
16i CO
®
25 | 76