Functional Test - Beko BEKOMAT 16i CO Translation Of Original Installation And Operation Manual

Table of Contents

Advertisement

BEKOMAT
®
16i CO
Illustration
26
E
50

10.3.2 Functional test

Illustration
54 | 76
Wear part replacement
Description / explanation
14. Screw the valve unit [E] using the screws [26].
15. Tighten the screws [26] with a torque of
2.5 Nm +/- 0.5 Nm (1.84 ft-lb +0.37 ft-lb).
16. Fit the solenoid valve connector [50] and screw tight
49
using the screw [49].
17. Tighten the screw [49] with a torque of
1.0 Nm +0.2 Nm (0.74 ft-lb +0.15 ft-lb).
Description / explanation
Press the TEST button for 2 ... 5 seconds.
0 The red ALARM LED is off.
0 The green VALVE LED is on.
0 The green POWER LED is on.
0 The valve opens and condensate is drained.