BEKOMAT
®
16i CO
Wrong
> 10 m (32.8 ft)
32 | 76
Right
≤ 10 m (32.8 ft)
Original installation and operation manual
Description / explanation
Drain line version
•
Do not use shut-off valves in the drain line.
•
Only connect the BEKOMAT
line using a hose.
0 The hose compensates for assembly
tolerances, vibrations and thermal
expansion.
•
Do not install the drain line on storage or
transportation surfaces.
•
The drain line may be a maximum
of 10 m (32.8 ft) long and installed at a
maximum of 5 m (16.25 ft) rise.
0 The minimum operating pressure
increases by 0.1 bar(g) (1.5 psi(g)) per
metre of incline.
Manifold design
•
The cross-section of the manifold must be at
least equal to the sum of the individual cross-
sections of the connected feed lines.
•
Lay the manifold with a continuous slope
> 3 %.
Diameters of the connected lines
•
The minimum diameter of the feed line and
the drain line must be at least 1/2" (interior
diameter at least 13 mm (0.5 in)).
•
Do not fit any reductions in the line (e.g. using
reducing nipples or fittings).
Bypassing filters
•
Discharge the condensate at each condensate
collection point using a separate BEKOMAT
•
Do not create any filter bypass points.
to the drain
®
.
®