Wrong
> 10 m (32.8 ft)
32 | 76
Right
≤ 10 m (32.8 ft)
Original installation and operation manual
Description / explanation
Drain line version
Do not use shut-off valves in the drain line.
Only connect the BEKOMAT
line using a hose.
0 The hose compensates for assembly
tolerances, vibrations and thermal
expansion.
Do not install the drain line on storage or
transportation surfaces.
The drain line may be a maximum
of 10 m (32.8 ft) long and installed at a
maximum of 5 m (16.25 ft) rise.
0 The minimum operating pressure
increases by 0.1 bar(g) (1.5 psi(g)) per
metre of incline.
Manifold design
The cross-section of the manifold must be at
least equal to the sum of the individual cross-
sections of the connected feed lines.
Lay the manifold with a continuous slope
> 3 %.
Diameters of the connected lines
The minimum diameter of the feed line and
the drain line must be at least 1/2" (interior 
diameter at least 13 mm (0.5 in)).
Do not fit any reductions in the line (e.g. using 
reducing nipples or fittings).
Bypassing filters
Discharge the condensate at each condensate
collection point using a separate BEKOMAT
Do not create any filter bypass points.
to the drain
®
.
®