2
Connection work - series connection
Connection cable [X9]
Connection cable [X8]
B
4
6
10
C
4
5
1
Description / explanation
7. Fit the cable gland components [4, 5, 6] over the
connection cable [X8] and insert the connection
cable [X9].
8. Insert the connection cable [X9] into the
left cable gland [C].
9. Insert the connection cable [X8] into the
right cable gland [B].
10. Connect connection cable [X8] and connection
cable [X9] according to the terminal diagram "4.7
Terminal diagram power control board" on Page 28.
5
11. Draw cable [X8] and connection cable [X9] taut.
6
12. Screw the cable gland components [4, 5, 6] onto the
X8
right cable gland [B] and the left cable gland [C].
X9
13. Fit the screw terminal [10].
14. Set the top cover [2] in place and insert the screws [1].
15. Tighten the screws [1] with a torque of
0.5 Nm +0.30 Nm (0.37 ft-lb +0.22 ft-lb).