Original installation and operation manual
6.2 Assembly conditions
Wrong
Right
mm
(inch)
> 3%
> 3%
> 3%
Description / explanation
Minimum installation height
•
The inlet height must be located lower than
the lowest point of the collecting tank, at
least 185 mm (7.28 in).
Continuous slope >3 % in hoses
•
When using hoses as the feed line, ensure a
continuous slope >3 %.
•
Do not form water pockets.
Continuous slope >3 % in pipes
•
When installing the feed line pipe, ensure a
continuous slope >3 %.
•
Do not form water pockets.
•
If installation height is limited, install the
lower inlet with a separate venting line.
Continuous slope >3 % in pipes
•
When installing the feed line pipe, ensure a
continuous slope >3 %.
•
Do not form water pockets.
BEKOMAT
16i CO
®
31 | 76