Always turn OFF the power before the f o l l o w i n g maintenance procedures a r e
carried out.
5-1

FUSE REPLACEMENT

The unit does not work i f the fuse i s blown.
reason.
I f the reason i s r e l a t e d to something outside t h i s u n i t , remedy
before r e p l a c i n g with new fuse.
unit, contact your dealer or d i s t r i b u t e r .
§When the fuse i s blown, replace in accordance with the following procedure.
Make absolutely sure to remove the power cord from the AC i n l e t .
not done, fuse replacement i s impossible.
The b u i l t - i n fuse i s a 0. 5A slow blow fuse i n areas with 100V,
supply.
b u i l t - i n .
1)
S l i d e the fuse holder cover ( t r a n s l u c e n t p l a s t i c ) on the rear panel to
the l e f t . ( I f the power cord has not been removed, the cover cannot be
s l i d . )
2)
When the cover opens, a b l a c k p l a s t i c hook marked FUSE PULL can be
seen i n front of the fuse.
fuse i s released from the right-hand c l i p . (See F i g . 6)
3)
Remove the blown fuse and place a new fuse i n the c l i p .
4)
Slide the cover to the right u n t i l i t reaches the o r i g i n a l position.
This completes the fuse replacement.
36

5. MAINTENANCE

In areas with 220V, 240V power supply, a 0.3A slow blow fuse i s
Replace with a fuse that conforms to the p a r t i c u l a r ratings.
I f the fuse i s blown, locate the
I f the problem stems from something i n the
When the hook i s pulled s t r a i g h t out, the
I f t h i s i s
120V power