Preset position function
This function can be used to register and delete up to 16 patterns of the current ranges of captured data (PTZ values) as
preset positions for one specified network camera.
Moving to a registered preset position is also available.
Registering and deleting preset positions, and moving to a registered preset position can be performed in the "Preset Position
Settings" screen or a sample screen of a GOT.
• "Preset Position Settings" screen (Page 111 Preset Position Setting (Camera Recorder Module))
• Sample screen of a GOT (Mitsubishi Electric Programmable Controller Camera Recorder Module RD81RC96-CA
Sample Screen Manual (BCN-P5999-1333)
*1 Can be downloaded from the Mitsubishi Electric FA website.
Moving to a preset position is also available in the buffer memory of a camera recorder module.
■Registering a preset position
The range of data captured by a specified network camera can be written to the flash memory of a camera recorder module.
Up to 16 patterns of preset positions can be registered for one network camera.
Each preset position is numbered, and the current range of data captured by a network camera is stored as preset position
information for each number.
If registering preset position information fails, a preset position registration error (error code: 1C60H) occurs.
Preset position information that can be registered is as follows:
Name
Preset position name
Position information (P)
Position information (T)
Position information (Z)
*1 The following cannot be used. (Note that no error message is output when entering surrogate pair characters and combining
characters.)
Characters other than ones in the Basic Multilingual Plane (U+10000 to U+10FFFF)
Line feed codes (U+2028, U+2029)
Surrogate pairs (0xD800 to 0xDBFF, 0xDC00 to 0xDFFF)
Control codes (U+0000 to U+001F, U+0080 to U+009F, U+00A0 to U+00BF, U+FFFE, U+FFFF)
Combining characters
• If preset position information is already registered, it is overwritten when registering a preset position. Check
the current preset position information before registering it.
• If the power of a camera recorder module is turned OFF while registering a preset position, the preset
position information may be lost. Do not turn the power OFF during registration.
• If the preset position registration count upper limit is reached, a preset position registration count upper limit
reach error (error code: 1CA0H) occurs.
■Deleting a preset position
Registered preset position information can be deleted from a camera recorder module.
After deletion, preset position information returns to its initial value.
When deleting a network camera in the setting screen of the module extended parameter and writing module extended
parameters to a camera recorder module, preset position information of the corresponding network camera retained at the
time of startup is also deleted from the camera recorder module.
If deleting preset position information fails, a preset position deletion error (error code: 1C70H) occurs.
7 CAMERA RECORDER MODULE (DETAILED SPECIFICATIONS)
246
7.1 Function Details
*1
)
Description
The name of a preset position
A pan value (horizontal direction) when registering a preset position
A tilt value (vertical direction) when registering a preset position
A zoom value (zoom in/out) when registering a preset position
Range
Number of characters: Up to 32
characters
Available characters: Basic
*1
Multilingual Plane in UTF-16LE
-1000 to 1000
-1000 to 1000
0 to 1000