Operating Status - Mitsubishi Electric MELSEC iQ-R Series User Manual

System recorder
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Operating status

The following table shows the operating status of the recording function for each recording setting.
The operating status can be checked in the "Recording Monitor" screen or in the buffer memory
camera recorder module. (Page 143 RECORDING MONITOR, Page 221 Recording status area (Un\G1500 to 3199),
Page 271 Recording status area (Un\G1500 to 3199))
*1 Buffer memory of a module set as the main one when configuring multiple modules
Page 67 Operation of the recording function when configuring multiple modules
Operating status
Stopped
Preparing
Operating
File saving trigger satisfied
Saving
*2 Main module and sub modules with recording target data
'1' is stored in 'Data sampling' (Un\G1506, Un\G1706, Un\G1906, Un\G2106) of a recorder module/camera
recorder module while devices and labels are being sampled and accumulated.
When selecting "File Saving Trigger Only" for the recording method, '1' is stored in 'In recording operation'
(Un\G1501, Un\G1701, Un\G1901, Un\G2101)
When selecting "Recording Startup Trigger + File Saving Trigger" for the recording method, '1' is stored in
'Data sampling' after a recording startup trigger is satisfied.
(Page 221 Recording status area (Un\G1500 to 3199), Page 271 Recording status area (Un\G1500 to
3199))
*3 Buffer memory of a module set as the main one when configuring multiple modules
Page 67 Operation of the recording function when configuring multiple modules
Precautions
Regardless of the recording method, devices and labels are accumulated while '1' is stored in 'Data sampling' (Un\G1506,
Un\G1706, Un\G1906, Un\G2106). For example, if "Trigger Instruction" is selected for the sampling method and '1' is not
stored in 'Data sampling,' devices and labels are not accumulated even when executing the DATATRG instruction.
(Page 44 Sampling methods of devices and labels, Page 221 Recording status area (Un\G1500 to 3199), Page 271
Recording status area (Un\G1500 to 3199))
Description
The recording function is stopped.
When configuring multiple modules, the function is stopped for all modules
function when configuring multiple modules)
The status is 'stopped' in the following cases:
• After starting a recorder module/camera recorder module
• After resetting a CPU module
• No recording settings written
Operations such as analysis of a recording setting are being prepared.
When configuring multiple modules, operations for all modules
recording function when configuring multiple modules)
The function is running.
When configuring multiple modules, the function is running on all modules
function when configuring multiple modules)
In this state, devices and labels are sampled in a CPU module according to the sampling method regardless of whether
a recording startup trigger is satisfied and a recording file is saved. (Page 44 Sampling methods of devices and
labels)
Note that a period for data accumulation differs depending on the recording method. (Page 18 Recording
methods)
A file saving trigger is satisfied and data for a remaining saving period is being sampled, received, and accumulated.
When configuring multiple modules, data for a remaining saving period is being sampled, received, and accumulated
*2
for all modules
. (Page 67 Operation of the recording function when configuring multiple modules)
A recording file is being saved.
When configuring multiple modules, recording files are being saved for all modules
recording function when configuring multiple modules)
If the status switches to 'saving' for multiple recording settings, the settings are saved in order from one that switches
first.
*2
*2
are being prepared. (Page 67 Operation of the
*2
*3
then in 'Data sampling.'
*1
of a recorder module/
. (Page 67 Operation of the recording
. (Page 67 Operation of the recording
*2
. (Page 67 Operation of the
1 FUNCTIONS
1.1 Recording Function
1
63

Advertisement

Table of Contents
loading

Table of Contents