a.
Insert the intrusion switch onto the holder on the fan cage and push it in the direction as
shown until it is fully seated.
b.
Fix the intrusion switch cable into the cable clip.
c.
Route the cable into the fan cage through the pre-cut slots on the foam and fan cage
bottom.
d.
Insert the intrusion switch connector into the connector keyhole, and move it in the shown
direction until it is fully seated.
Step 3.
Install the fan cage back into the chassis. See
Step 4.
Install system fans into the fan cage. See
After you finish
Complete the parts replacement. See
M.2 drive and M.2 backplane replacement
Follow instructions in this section to remove and install the M.2 drive and M.2 backplane.
•
"Remove an M.2 drive" on page 83
•
"Install an M.2 drive" on page 84
•
"Remove the M.2 backplane" on page 86
•
"Install the M.2 backplane" on page 88
Remove an M.2 drive
Follow instructions in this section to remove an M.2 drive.
About this task
Attention:
• Read
"Installation Guidelines" on page 39
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
"Power off the server" on page
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
• Before you remove or make changes to drives, drive controllers (including controllers that are integrated
on the system board assembly), drive backplanes or drive cables, back up all important data that is stored
on drives.
"Install the system fan cage" on page
"Install a system fan" on page
"Complete the parts replacement" on page
and
"Safety inspection checklist" on page 40
48.
157.
164.
.
Chapter 5
Hardware replacement procedures
160.
to ensure that you
83