3.2.4
V.24 Line Interface Cable for GR2000-B
This interface cable for the GR2000-B when used as DCE. For connecting the
GR2000-B to a V.24 line interface on the terminal, use HN-F9531-B75H (5 m). The
boundary with the network is the receptacle on the DTE-attached cable. Figure 3-6
below is the diagram of the V.24 line interface cable.
HDRA 68-Pin Connector
(For Router)
Figure 3-6 V.24 line interface cable
Make sure that the line speed is 64 kbit/s or less and the maximum cable length
from the GR2000-B to the DTE (terminal) is 16 m or less.
Consult Hitachi if you purchase a cable other the 5 m cable specified above, since
line speed differs depending on the length of a cable. Figure 3-7 below shows the
limitations on the length of cables.
DCE
Router
Figure 3-7 Cable Length Limitations
GR2K-GA-0007
Rev. 5.00
Cable for Router
Connection of cable connectors
Cable length=5m
Cable length=16m or less
Preparing Interface Cables and the Terminal
D-Sub 25-Pin Receptacle Connector
(For Terminals)
Cable for modems (to be prepared by customer)
Cable Length=Xm
M2.6
DTE
,
WS/PC, etc
3-7