WARNING:
Due to the weight of a fully populated MX7000 enclosure chassis, never install or pull a full chassis
out of a rack with ReadyRails. First remove each component before you lift or remove the chassis.
Right control panel module
Right control panel ear
Right control panel cable
Left control panel module
Left control panel ear
Control panel flex cable
Instructions for before and after right control panel replacement with OME-M 1.3.0
and above
The below table provides set of instructions for lead chassis, member chassis or chassis not in MCM group:
NOTE:
MX7000 can automatically backup and restore configurations stored in RCP and MCM data for OME-M version
1.3.0 and above.
Table 12. Instructions for before and after right control panel replacement with OME-M 1.3.0 and above 
#
Order of actions
1
Replace RCP.
2
Chassis Service Tag will be automatically
programmed.
3
The chassis configurations are restored
automatically.
4
If the chassis is configured to have DHCP IP,
then there may be new IP assigned to the
chassis by the DHCP server (as MAC address
changes in RCP replacement).
NOTE:
Display of new IP indicates that the chassis configuration is restored successfully.
Instructions for before and after right control panel replacement with OME-M
version lower than 1.3.0
The below tables provide information on set of instructions for each type of chassis role:
● Chassis not in the group
● Chassis is member of a group
● Chassis is the lead of a group
Table 13. Chassis is not part of MCM group 
#
Order of actions
1
Take Chassis Backup using OME-M GUI.
2
Replace RCP.
3
Program Chassis Service Tag using racadm:
4
Restore the previous Backup using OME-M
GUI.
32
Field service information
Details
Refer to
Checking the chassis configuration restoration status with
OME-M version
for details.
NA
Refer to
Checking the chassis configuration restoration status with
OME-M version
for details.
NA
Details
If no previous chassis backup data exists, perform this step to take a new
chassis backup. Persistent storage on RCP needs to be fully functional
for a successful backup. Refer to OME-M API Guide for details
NA
racadm config -g cfgRacTuning -o cfgRacTuneServiceTag <SVC_TAG>
Refer to OME-M User's guide for details