WARNING:
Due to the weight of a fully populated MX7000 enclosure chassis, never install or pull a full chassis
out of a rack with ReadyRails. First remove each component before you lift or remove the chassis.
●
Right control panel module
●
Right control panel ear
●
Right control panel cable
●
Left control panel module
●
Left control panel ear
●
Control panel flex cable
Instructions for before and after right control panel replacement with OME-M 1.3.0
and above
The below table provides set of instructions for lead chassis, member chassis or chassis not in MCM group:
NOTE:
MX7000 can automatically backup and restore configurations stored in RCP and MCM data for OME-M version
1.3.0 and above.
Table 12. Instructions for before and after right control panel replacement with OME-M 1.3.0 and above
#
Order of actions
1
Replace RCP.
2
Chassis Service Tag will be automatically
programmed.
3
The chassis configurations are restored
automatically.
4
If the chassis is configured to have DHCP IP,
then there may be new IP assigned to the
chassis by the DHCP server (as MAC address
changes in RCP replacement).
NOTE:
Display of new IP indicates that the chassis configuration is restored successfully.
Instructions for before and after right control panel replacement with OME-M
version lower than 1.3.0
The below tables provide information on set of instructions for each type of chassis role:
● Chassis not in the group
● Chassis is member of a group
● Chassis is the lead of a group
Table 13. Chassis is not part of MCM group
#
Order of actions
1
Take Chassis Backup using OME-M GUI.
2
Replace RCP.
3
Program Chassis Service Tag using racadm:
4
Restore the previous Backup using OME-M
GUI.
32
Field service information
Details
Refer to
Checking the chassis configuration restoration status with
OME-M version
for details.
NA
Refer to
Checking the chassis configuration restoration status with
OME-M version
for details.
NA
Details
If no previous chassis backup data exists, perform this step to take a new
chassis backup. Persistent storage on RCP needs to be fully functional
for a successful backup. Refer to OME-M API Guide for details
NA
racadm config -g cfgRacTuning -o cfgRacTuneServiceTag <SVC_TAG>
Refer to OME-M User's guide for details