Fan specifications
The PowerEdge MX7000 enclosure supports four front accessible hot-swap cooling fans and five rear accessible hot-swap
cooling fans. The cooling fan assembly ensures that the key components of the server such as the sleds, Fabrics, and I/O
modules get adequate air circulation to keep them cool. A cooling fan failure can result in overheating and may lead to damage.
Table 27. Supported fans
Fan location
Size
Number of fans
Redundancy
PSU specifications
The PowerEdge MX7000 enclosure supports up to six AC power supply units (PSUs).
Table 28. PSU specifications
Description
PSU
Class
Heat dissipation (maximum)
Frequency
Voltage
Current
Inrush current
Connector
CAUTION:
Mixed high line and low line AC inputs in the same enclosure is not supported.
NOTE:
Heat dissipation is calculated using the PSU wattage rating.
NOTE:
In an ideal input voltage condition and over the entire enclosures ambient operating range, the inrush current may
reach 120 A per power supply for 10 ms or less.
NOTE:
This enclosure is also designed to connect to the IT power enclosures with a phase-to-phase voltage not exceeding
240 V.
Ports and connectors specifications
USB ports
The PowerEdge MX7000 enclosure supports two Type A, USB 2.0 ports on the front panel.
Mini DisplayPort
The PowerEdge MX7000 enclosure supports one Mini DisplayPort (mini DP) on the front panel.
76
Technical specifications
Front
60 mm
4
3+1
Specification
6 x 3000 W AC
Platinum
1205 BTU/hr
50/60 Hz
100–240 V AC, autoranging
6 x 16 A
Maximum 40 A per power supply for 10 ms or less
Maximum 50 A per power supply for 1.2 ms or less
C22 AC power connector
Rear
80 mm
5
4+1