Dell EMC PowerEdge MX7000 Field Service Manual page 39

Hide thumbs Also See for EMC PowerEdge MX7000:
Table of Contents

Advertisement

Figure 40. Inserting the control panel board
4. Use a Phillips #1 screwdriver, fasten the screws to secure the control panel cover with the control panel bracket.
Next steps
1.
Install the right control panel
CAUTION:
After replacing the right control panel module/ CMOS battery, ensure to restore the chassis
configuration. For more information, see
Restoring the chassis configuration
About this task
You can restore the configuration of a chassis using a back up file, if the backed-up configuration is of the same chassis. You
must have the chassis administrator role with device configuration privilege to restore the chassis.
To restore a chassis configuration:
Steps
1. On the chassis Overview page, click More Actions > Restore.
The Restore Chassis window is displayed.
2. In the Restore File Location, select the Share Type to locate the configuration backup file.
3. Enter the Network Share Address, and Network Share Filepath of the backup file.
4. Enter the name of the Backup File.
5. If the Share Type is CIFS, enter the Domain, Username, and Password to access the shared location. Else, you can skip
this step.
6. In the Restore File Password section, enter the Encryption Password to open the back up file.
7. Click Restore to restore the chassis configuration.
A message is displayed indicating that the chassis is successfully restored.
NOTE:
You can check the status of the restore process in the Jobs page. To view the progres, click Montitoring >
Jobs.
ear.
Restoring the chassis
configuration.
Field service information
39