Rack Installation
Installing the enclosure into the rack
The PowerEdge MX7000 enclosure is offered with Static rails (C5). Static Rails do not support the ability to service the
enclosure in the rack and are not compatible with a CMA.
The following steps are procedures to install the enclosure into the rack:
WARNING:
To avoid injury, do not attempt to lift the enclosure by yourself. Dell recommends that a minimum of
two people lift the enclosure.
1. Pull the four enclosure handles upward, and lift the enclosure.
2. Align the rear of the enclosure with the rails and slide the enclosure into the rack.
Figure 69. Installing enclosure into the rack
a. When the rear enclosure handles are near the rack flange, press the blue release buttons on the sides of each enclosure
handle, and push the handles down until it locks into place.
Figure 70. Sliding the enclosure into the rack
b. Push the enclosure into the rack.
c. When the enclosure handles are near the rack flange, press the blue release buttons on the sides of each enclosure
handle, and push the handles down until it locks into place.
d. Slide the enclosure into the rack until it is firmly seated.
3. Tighten the captive screws on the front panel of the enclosure.