HP Metal Jet S100 User Manual page 104

Powder management station
Hide thumbs Also See for Metal Jet S100:
Table of Contents

Advertisement

2.
Open the lid of the vacuum hose connection to the sieve on the sieve's rear cover.
3.
Connect an explosion-protected vacuum cleaner and turn it on.
NOTICE:
in)), use adapters (50, 60, and 65 mm (1.97, 2.36, and 2.56 in)) to change the diameter.
WARNING!
4.
When finished, turn off the vacuum cleaner and unplug the hose.
5.
Close the lid of the vacuum hose connection on the sieve's rear cover.
Finish cleaning
Always follow the steps of the procedure in the order presented.
Ensure that all windows, covers, and doors are closed and in their original positions.
WARNING!
Finish the replacement
Follow these steps to finish the replacement.
1.
After completing the replacement, reassemble all the components by following the replacement
steps in the reverse order. See
2.
Screw in the sieve left lateral cover.
3.
Ensure that all windows, covers, and doors are closed and in their original positions.
100
Chapter 4 Maintenance
If your vacuum hose is different in diameter from the load station's connector (38 mm (1.5
Do not use a compressed-air gun.
Explosion hazard. Mechanical sparks, static electricity may be generated.
{Xref Error! Target does not exist.}

Advertisement