3.
From the left menu of the Front Panel, select the settings icon
clean sieve.
NOTE:
the left menu of the Front Panel, select the tasks icon
Quick clean sieve.
4.
Connect the external vacuum cleaner to the sieve cleaning inlet and turn it on. The inlet is located
at the back of the station. There is an adapter for different vacuum nozzle sizes.
NOTICE:
(1.5 in)), use adapters 50, 60, and 65 mm (1.97, 2.36, and 2.56 in) to match the diameter.
5.
Tap Next on the Front Panel. The process starts and the Front Panel displays its progress.
6.
The Front Panel tells you when the vacuuming has finished. Tap to confirm.
7.
Turn off the external vacuum cleaner and disconnect it from the Load station. Ensure that the lid of
the vacuum hose connection on the sieve's rear cover is closed.
8.
Tap Done on the Front Panel.
Set up recipes
Change to process development mode to be able to edit the recipes.
From the left menu of the front panel, select the settings icon
Process development.
For build-unit loading
Follow one of two paths to view or edit the recipe.
Access through 'Load BU'
1.
From the left menu of the front panel, select the production icon
You can also access the quick-clean sieve process through the maintenance tasks. From
If your vacuum hose is different in diameter from the Load station's connector (38 mm
, then tap Maintenance > Quick
. Navigate to On demand tasks and tap
, then tap Utilities > Device mode >
, then tap Load BU.
Set up recipes