The SV9100 GCD-CP10 can slow down when the DIM is running on a busy SV9100 system. This is
unavoidable, as the GCD-CP10 must process all system activity and output the corresponding information to
the DIM.
T
L
S
3
O
OG
ECTION
Access to the DIM has changed from the SV8100 in the following way:
Access via port number 5963 is not available, this has been completely removed and cannot
be enabled.
User ID monimoni and password hihi are not available.
Access must now be enabled on each system via the user access to the DIM.
User Access to the DIM
PRG Command setup
10-20-06 –
DIM Output – Enter the TCP Port for DIM Access (eg 5964)
90-31-01 –
Enable DIM access
Username (default = SV9100)
Password (default = 12345678)
Easy Edit
Advanced Items – Maintenance – DIM Access Password
Note - It is strongly recommended that you change the default username and password after
enabling DIM access.
System Maintenance Manual