UNIVERGE SV9100
* PORT STATUS (40001 --> 0)*
PORT (PHYS)
STATUS
00040001h(00000007h) :
--------h(--------h) :
--------h(--------h) :
--------h(--------h) :
--------h(--------h) :
--------h(--------h) :
--------h(--------h) :
--------h(--------h) :
00000009h(00000008h) :
0000000Ah(00010008h) :
--------h(--------h) :
--------h(--------h) :
--------h(--------h) :
--------h(--------h) :
--------h(--------h) :
12:15:13 >>
To display the status of trunk ports 1 through to 10:
m
status trk 0001 000a
o
To display the information related to the Blade installed into a slot:
m
slot info nn
Where nn is the slot number 01 to 24 in hexadecimal (example – an ESIU in slot 1 will show the following):
slot info 01
Slot information) Slot ID : 1
Status : RUNNING
Logical unit ID : ESIU
Dump down message : Disable
Number of Tx errors : 1
Slot started delay : 2.83sec.
Common unit driver information)
Slot ID : 1
System Maintenance Manual
CALL
HOLD CONDITION
IDLE( 0h) 00000000h 00000000h
(----h) --------h --------h no station port is assigned
(----h) --------h --------h no station port is assigned
(----h) --------h --------h no station port is assigned
(----h) --------h --------h no station port is assigned
(----h) --------h --------h no station port is assigned
(----h) --------h --------h no station port is assigned
(----h) --------h --------h no station port is assigned
IDLE( 0h) 00000000h 00000000h
IDLE( 0h) 00000000h 00000000h
(----h) --------h --------h no station port is assigned
(----h) --------h --------h no station port is assigned
(----h) --------h --------h no station port is assigned
(----h) --------h --------h no station port is assigned
(----h) --------h --------h no station port is assigned
Slot
Enter
Function
slot
List the slot commands
available.
DIM Output
SLOT RX
Rx simulation
SLOT TX Tx a packet (DSP,64K)
SLOT TXB
Tx a packet (128K)
SLOT TXC
Tx a packet (LKTS C/0)
SLOT TXK
Tx a packet (LKTS KTEL)
SLOT TXS
Tx a packet (LKTS STA)
SLOT RESET
Reset unit/slot
SLOT INFO
Slot/Unit info
SLOT DUMP
Dump Tx message SLOT
KEEPALIVE
Keep alive control SLOT IF
Slot interface
SLOT WATCHSUBME(only PRI) watch SUBME
Issue 1.0
35