UNIVERGE SV9100
Alarm
Type
Name
No.
7
Major Power failure
8
Major RAM Backup
Battery Error
9
Not set --- Reserved ---
10
Not set ISDN Link Error Layer1 link of ISDN lines
11
Not set CTI Link Error
12
Not set ACD MIS Link
Error
System Maintenance Manual
Content of Alarm
The supply of the
• The power cable came off.
commercial power
stopped.
• Power failure
• The power supply unit
broke down.
RAM backup battery on
the CD-CP00-US blade is
unplugged or defective.
• Connected determination
came off.
of main device and ISDN line
• Breakdown of DSU
• The setting of PRG10-03 is
not corresponding to an
actual line.
The link with the CTI
• LAN cable defective.
server came off.
• Connected HUB broken.
• The CTI server doesn't
start normally.
The link with ACD MIS
• LAN cable defective.
client PC came off.
• Connected HUB broken.
• The CTI server doesn't
start normally.
Cause
Action
Confirm the power
supply outlet when
the commercial power
has not stopped.
Please inquire of the
manufacturer when
the problem occurs.
Check the battery
connector. If it is
connected correctly,
replace the battery.
Confirm the data of
PRG10-03.
Reconfirm wiring and
the installation of DSU.
Please inquire of the
manufacturer when
the problem occurs
after it confirms it.
Please reconfirm the
CTI server, wiring, and
the connection.
Please inquire of the
manufacturer when
the problem occurs
after it confirms it.
Please confirm ACD
MIS client PC and
connected part.
Please inquire of the
manufacturer when
the problem occurs
after it confirms it.
Issue 1.0
Recovery
When the
commercial power
is restored, the
error is recovered.
The error is
recovered once
the battery is
replaced.
When the
connection returns
normally, the error
is recover.
When the
connection returns
normally, the error
is recover.
When the
connection returns
normally, the error
is recover.