Output the Alarm Report to a USB stick

The alarm report can be output to the memory stick installed into the USB socket of the GCD-CP10 card.
The report is generated via the Maintenance Service code.
Ensure you assign a Service Code to the Maintenance code in CMD 11-10-42 (default = none assigned).
To Output the report
Ensure a USB Memory stick is installed to the USB drive of the GCD-CP10 card
Ensure you assign a Service Code to the Maintenance code in CMD 11-10-42 (default = none assigned)
From a Keytelephone go off hook and dial the Maintenance Service Code
MAINTENANCE
FUNCTION NO(1-3) ?
Enter 2 on the keypad
ALMRPT SAVE TO USB
#: NEW *:ALL
Enter # on the keypad to output new alarms since??
Or enter * on the keypad to output all alarms
While saving the display shows
ALMRPT SAVE TO USB
START SAVE
When complete the display shows
ALMRPT SAVE TO USB
SAVE COMPLETE
Press SPK or go on hook to end
The alarm report is saved as a text file.