Issue 1.0
Alarm
Type
No.
4
Minor PKG S/W
Download Error
5
Major Cooling fan error The cooling fan does not
6
Not set Blocking
70
Name
Content of Alarm
The unit program was
not able to be
downloaded normally.
The unit was not able to
be started normally.
work normally.
The link of terminals
connected with the ESI
package came off.
Cause
The package software is not
stored in the downloaded
USB memory.
The stored package
software is illegal.
Package information that
had been installed before
remains.
The cooling fan has stopped
working.
The cooling fan has come
off.
• Breakdown of terminal.
• Faulty wiring and wiring
determination.
• External noise.
• Breakdown of ESI package.
UNIVERGE SV9100
Action
Recovery
Delete slot
Please exchange
information that
units, though it is
corresponds by
likely to restore by
PRG90-05-01 to delete
mounting the unit
package information
again.
that had been
installed before.
When the unit
program is
There is a possibility
normally
that the unit program
downloaded, the
is broken though an
error is recovered.
external factor of the
noise etc. is thought.
Please load into the
USB memory and try
again when you back
up the unit program.
Please inquire of the
manufacturer when
not restoring it.
Confirm that the
Replace the
cooling fan is turning.
cooling fan if it is
defective.
Verify the mounting of
the cooling fan.
Confirm the terminal
The error is
connected with same
recovered when
ESI. If they work
reconnecting or
normally, confirm the
exchanging it.
breakdown or the
wiring for the
terminal. Exchange the
terminal that doesn't
work and the working
terminal, and confirm
it's working. An
external factor of the
noise etc. is thought.
Please reconfirm
wiring and the
installation,etc.
Please inquire of the
manufacturer when
the problem occurs
after it confirms it.