Place Test Set on output of paging at
chassis port or PGD(2)-U10 ADP with all
external wiring removed.
Yes
page heard on test set?
External amplifier or PRG 11-01
and PRG 11-10 ~
PRG 11-15
System Maintenance Manual
External Paging Problems
Yes
No
External
Check PRG 11-01 and PRG 11-10 ~ PRG 11-15
for correct access code (external) for paging.
Access Code
correct?
Yes
1.
Reset/replace PGD(2)-U10 ADP, and test.
2.
Perform Second Initialization, and test; then perform
First Initialization and test.
3.
Replace GCD-CP10 and test using default program.
G1
No
Amplifier
Install amplifier.
provided?
No
Pass
Retest using correct
access code.
Fail