Issue 1.0
Real unit ID : 12H
Version : 1.8
Lines / unit : 8
Block switch : RUN
Timeslot : 000H-00FH (16)
slot info 03 Slot information)
Slot ID : 3
Status : RUNNING
Logical unit ID : BRIU
Dump down message : Disable
Number of Tx errors : 0
Slot started delay : 468.99sec.
Common unit driver information)
Slot ID : 3
Real unit ID : 60H
Version : 3.3
Lines / unit : 2
Block switch : BLOCK
Timeslot : 040H-043H (4) BRIU driver information)
m
To reset the Blade installed in a slot:
slot reset nn
Where nn is the slot number 01 to 10 in hexadecimal.
The Blade is reset, any calls in progress at the Blade are disconnected. The Blade operates normally after the
reset.
The reset has the same operation as removing and re-installing the Blade.
(example – to reset the Blade in slot 3 = slot reset 03)
o
Detector
36
Firmware loaded onto the Blade
Number of ports on the card (8ESIU)
Firmware loaded onto the blade
Number of ports on the card (2BRIU)
Block switch set to BLOCK
Enter
Function
Detector
List the status of the
DTMF/Tone detectors on
the GCD-CP10(and DSPDB if
installed).
Block switch set to RUN
DIM Output
Number of Channels = 64 CPRU = 32 , DSPDBU
= 32
No
Type
01(1401) DTMF ACTIVE 000d
02(0000) NOT USED
03(0000) NOT USED
04(0000) NOT USED
05(0000) NOT USED
:
:
64(0000) NOT USED
System Maintenance Manual
UNIVERGE SV9100
Status Target
READY 0000
READY 0000
READY 0000
READY 0000
:
:
READY 0000

Advertisement