Welded Tub Assembly; Front Counterweight - Electrolux EWM09311 Service Manual

Washing machines with electronic control system
Table of Contents

Advertisement

WM 50liter(Full size)
Spring (diameter 4mm; length 183mm)
maximum spring load: load 30kg±2 elongation spring
Spring position on tub:
WM 50liter(Full size) - Only one position on the tub

23.5.5 Welded tub assembly

Remove the back panel (see relevant paragraph).
Remove the worktop (see relevant paragraph).
Remove the detergent dispenser (see relevant paragraph).
Remove the whole control panel (see relevant paragraph).
Remove the bellow seal (see relevant paragraph).
Remove the solenoid valve (see relevant paragraph).
Remove the pressure switch including the small pipe (see relevant paragraph).
Disconnect the heating element cabling from the NTC probe and motor.
Set down the appliance in a horizontal position on a protected surface in order not to damage the unit.
Remove the shock absorbers (see relevant paragraph).
Remove the suspension springs.
Slacken the clamp that holds the tub drain pipe to the filter unit assembly.
Slide out the tub.
During re-assembly, take care when re-positioning the Bostik sealant in the right place and re-position the dot
in the drain pipe.

23.5.6 Front counterweight

Follow the same steps described previously for the welded tub assembly, except the last paragraph where it
talks about the sealant.
Screw in the retaining screws when re-assembling the counterweight onto the tub.
123/124
Technical Support - DMM
599 75 58-67 Rev.04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ewm09312Ewx13611Ewx14931

Table of Contents