The other alarms are displayed by a code.
The alarms are enabled during the execution of the washing programme. With the exception of alarms
associated with the configuration and the power supply voltage/frequency, which are also displayed during
the programme selection phase.
The door can normally be opened (except where specified) when an alarm condition has occurred, on
condition that:
•
The level of the water in the tub is below a certain level.
•
The water temperature is lower than 55°C.
•
The motor has stopped.
Certain alarm conditions require a drain phase to be performed before the door can be opened for safety reasons:
•
Cooling water fill if the temperature is greater than 65°C.
•
Drain until the analogue pressure switch is on empty, during a max. 3 minute interval.
10.2 Reading the alarms
The last three alarms stored in the FLASH memory of the PCB can be displayed:
•
Enter the diagnostic mode (para. 9.1 or para. 9.2).
•
Irrespective of the type of PCB and configuration, turn the programme selector knob
clockwise to the eleventh position and the last alarm is displayed.
•
to display previous alarms, touch the sensor closest to the START/PAUSE sensor in
sequence (as shown in the figure).
•
To return to the last alarm, touch the START/PAUSE sensor.