17.3 Phases of the diagnostics test

Irrespective of the type of electronic board and of the selector configuration, once the diagnostics system has
been activated, turn the selector dial clockwise to run a check of the various components and read the alarms
(as described in table 1).
Concurrently, a control code of the selector (or of the second selector, where envisaged) is shown: in Z3
stylings on the display for two seconds, before displaying the contents of the last column in the table below,
whereas in Z6 stylings the code is displayed by the LEDs coming on for three seconds (see table 2).
All alarms are enabled in the diagnostic cycle.
Selector
position
-
1
-
-
2
-
-
3
-
-
4
-
-
-
6
-
-
-
7
-
-
-
8
-
9
----
10
- Reading/Deleting the last alarm
(*) In most cases, this time is sufficient to check the heating. However, the time can be increased by repeating the phase without draining the
water: pass for a moment to a different phase of the diagnostic cycle and then back to the heating control phase (if the temperature is
°
higher than 80
C, heating does not take place).
(**) The check at the maximum speed occurs without control of the AGS (anti-unbalancing system) and no garments must be inside the
appliance.
Technical Support - DMM
Components activated
All the LEDs come on in
sequence.
Pressing a button turns on
the corresponding group or
LED.
Door safety interlock
Wash solenoid valve
Door safety interlock
Pre-wash solenoid valve
Door safety interlock
Solenoid valve
pre-wash and wash
Door safety interlock
Wash solenoid valve, if the
water in the tub is not
enough to cover the heating
element
Heating element
Door safety interlock
Wash solenoid valve if the
water level in the tub does
not cover the heating
element
Motor (55 rpm clockwise,
55 rpm anticlockwise, pulse
at 250 rpm)
Door safety interlock
Drain pump
Motor up to 650 rpm then at
maximum spin speed. (**)
----
TABLE 1
Working conditions
Always active
Door closed
Water level below
anti-flooding level
Maximum time 5 mins.
Door closed
Water level below
anti-flooding level
Maximum time 5 mins.
Door closed
Water level below
anti-flooding level
Maximum time 5 mins.
Door closed
Water level above the
heating element.
Maximum time
10 mins up to 90°C.
(*)
Door closed
Water level above
the heating element
Door closed
Water level lower
than anti-boiling level
for spinning
----
-----
59/124
When a Display
Function tested
is present
User interface
functioning
Water fill to wash
compartment
Water level in
the tub (mm)
Water fill directly
to tub
Water level in
the tub (mm)
Water fill to
conditioner
Water level in
compartment
the tub (mm)
Reheating
Temperature in
°C measured
using the NTC
probe.
Check for leaks
from the tub.
Drum speed in
rpm/10
Drain, calibration
of analogue
pressure switch
Drum speed in
and spin
rpm/10
----
----
599 75 58-67 Rev.04