18 ALARMS
18.1 Displaying the alarms to the user
18.1.1 Z3 Styling
The alarms are displayed by the flashing red LED of the START/PAUSE button and simultaneously through the
Display.
The alarms displayed to the user are listed below:
E10 - Water fill difficulty (tap closed)
E20 - Drain difficulty (filter dirty)
E40 - Door open
18.1.2 Z6 Styling
Alarms are displayed by the red LED on the START/PAUSE button flashing along with one of the three LEDs
above the START/PAUSE button.
The table below illustrates the various combinations of LED lightings.
E10
Water fill
difficulty
(tap closed)
The aforementioned alarms (for both versions) can be remedied directly by the end user.
While the alarms listed below (for both versions):
EF0 – Water leakage (Aqua Control System)
It is displayed to the user, but technical assistance is required to repair it.
EH0 – Voltage or frequency outside normal values
It is necessary to wait for power supply voltage and/or frequency to restore nominal conditions.
The alarms are enabled during the execution of the washing programme. With the exception of alarms
associated with the configuration and the power supply voltage/frequency, which are also displayed
during the programme selection phase.
The door can normally be opened (except where specified) when an alarm condition has occurred, on
condition that:
•
The level of the water in the tub is below a certain level.
•
The water temperature is lower than 55°C.
•
The motor has stopped.
Certain alarm conditions require a drain phase to be performed before the door can be opened for safety
reasons:
•
Cooling water fill if the temperature is higher than 65°C;
•
Drain until the analogue pressure switch is on empty, during a max. 3 minute interval.
Technical Support - DMM
E20
Drain
difficulty
(filter
fouled)
61/124
E40
Door open
599 75 58-67 Rev.04