omreport system thrmshutdown
Use the omreport system thrmshutdown command to view which properties, if any, have been
configured for a thermal shutdown action.
The three properties that display for thermal shutdown are disabled, warning, or failure. If the CLI
displays the following message, the thermal shutdown feature has been disabled:
Thermal protect shutdown severity: disabled
If the system is configured to shutdown when a temperature probe detects a warning or failure event, one
of the following messages displays:
Thermal protect shutdown severity: warning
Thermal protect shutdown severity: failure
omreport system version
Use the omreport system version command to list the version numbers of the BIOS, firmware, systems
management software, and operating system that are installed on your system.
Example Command Output
When you type:
omreport system version
the output that appears in your CLI window depends on the version of the BIOS, RAID controllers, and
firmware installed on your system. The following partial command results are unique and may not
resemble the results for your system's configuration:
Version Report
---------------------
Main System Chassis
---------------------
Name
Version
Updateable : N/A
Name
Version
Updateable : N/A
Name
Version
Updateable : N/A
48
omreport: Viewing System Status Using the Instrumentation Service
: BIOS
: 0.2.16
: BMC
: 0.26
: Primary Backplane
: 1.01