Table 4-12. omconfig chassis remoteaccess (continued)
name=value pair 1
config=
config=nic
(continued)
name=value pair 2
ipsource=static | dhcp | systemsoftware static: Static if the IP address of the BMC
nicselection=nic1 | teamednic1nic2 |
dracnic
privilegelevel=administrator | operator
| user
subnet=Subnet
omconfig: Managing Components Using the Instrumentation Service
Description
LAN interface is a fixed, assigned IP address.
dhcp: DHCP if the source of the IP address of
the BMC LAN interface is the dynamic host
configuration protocol.
systemsoftware: System software if the source
of the IP address of the BMC LAN interface is
from the system software.
NOTE:
Not all commands may be supported on
the system.
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC teaming
functionality.
dracnic: Enables DRAC NIC if DRAC 5 is
installed.
NOTE:
The option nicselection is supported
only on PowerEdge x9xx systems.
administrator: Sets the maximum privilege
level that can be accepted on a LAN channel
to Administrator.
operator: Sets the maximum privilege level
that can be accepted on a LAN channel
to Operator.
user: Sets the maximum privilege level that
can be accepted on a LAN channel to User.
subnet: Sets a subnet mask if you have
selected static as the IP address source for the
BMC LAN interface.