Fujitsu Eternus DX60 User Manual page 104

Disk storage system
Hide thumbs Also See for Eternus DX60:
Table of Contents

Advertisement

Chapter 5 Installation
5.2 Rack Installation
Procedure
1
2
Refer to "ETERNUS DX60/DX80/DX90 Disk storage system Package Contents"
to confirm there are no missing parts for the rack mount kit.
"ETERNUS DX60/DX80/DX90 Disk storage system Package Contents"
Refer
Attach the M5 cage nuts or M5 rack nuts to the rear rack pillar.
Use the M5 cage nuts if the rack pillar holes are square.
Use the M5 rack nuts if the rack pillar holes are round.
Attachment positions
On either side, insert eight M5 cage nuts or M5 rack nuts in the 1st, 3rd, 4th, and 6th
holes above the AC outlet box base line.
M5 cage nut or
(Rear rack pillars)
M5 rack nut
[Left]
6th position
4th position
2U
1U
1U
3rd position
1st position
Attachment procedure
M5 cage nut
Clip the cage nut tabs into the desired
hole from the inside.
Side view
M5 cage nut
Rack pillar (square)
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
Copyright 2011 FUJITSU LIMITED
M5 cage nut or
M5 rack nut
[Right]
6th position
4th position
AC outlet box
AC outlet box
3rd position
1st position
Base line of
AC outlet box
M5 rack nut
Clip the rack nut over the desired
hole from the side.
M5 Rack nut
Rack pillar (round)
104
P3AM-3042-08ENZ0