Chapter 9 Operation and Maintenance
9.4 Post Start-of-Operation Changes to the Configuration
9.4.1

Replacing Fibre Channel Cards

The following explains how to replace a failed Fibre Channel card.
Note that this is only an overview of the replacement procedure. Refer to the relevant manuals
for more details.
Refer
If ETERNUS SF Storage Cruiser is installed, refer to the ETERNUS SF Storage Cruiser manuals
and check necessary settings.
Refer
The procedure to replace a Fibre Channel card is as follows:
Procedure
1
2
2-1
2-2
3
3-1
3-2
4
User guide for Fibre Channel card
"ETERNUS Disk storage systems User's Guide -Server Connection-"
ETERNUS SF Storage Cruiser manuals
Before performing this procedure, use the ETERNUS DX60/DX80/DX90's GUI
or CLI to check the WWN (World Wide Name) or host affinity of the Fibre
Channel card that is to be replaced, and record this setting for later replication.
Replace the server-side Fibre Channel card.
Turn off the server for which the Fibre Channel card is to be replaced.
Replace the Fibre Channel card.
For details of the replacement procedure, refer to the user guide attached with the
Fibre Channel card.
Adjust the settings as necessary, using the ETERNUS DX60/DX80/DX90's GUI
or CLI.
Delete the setting of WWN or host affinity set to the uninstalled Fibre Channel card.
Referring to the information recorded in
or host affinity of the new Fibre Channel card in the ETERNUS DX60/DX80/DX90.
When the setting is complete, confirm that the server can access the ETERNUS
DX60/DX80/DX90.
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
Copyright 2011 FUJITSU LIMITED
Step
1, register the information such as WWN
205