Chapter 7 Setup

7.2 Basic Setup

❏ Settings for the PC
Perform the following procedure to set up the PC.
Procedure
1
2
3
7.2
Basic Setup
This section explains how to perform the basic setup for the ETERNUS DX60/DX80/DX90.
Turning on the ETERNUS DX60/DX80/DX90
Turn on the ETERNUS DX60/DX80/DX90 before starting setup.
For details on how to turn on the ETERNUS DX60/DX80/DX90, refer to
(page
When checking the connection between the PC and the ETERNUS DX60/DX80/DX90, execute
the "ping" command at the PC command prompt.
The following is an example of ping execution: ("192.168.1.1" is the default IP address)
If the execution results in error, check the PC's network settings.
Set the IP address and subnet mask of the PC.
Set the following values.
IP address: 192.168.1.2
Subnet mask: 255.255.255.0
Check the settings of the Web browser.
Proxy server and Cache: Disable
Java Script, style sheets, and cookies: Enable
Connect the PC to the MNT port of the ETERNUS DX60/DX80/DX90 Controller
0 (CM#0) directly with a LAN cable (for operation management).
When a LAN cable (for operation management) is connected to Controller 1 (CM#1),
disconnect it.
72).
ping 192.168.1.1
If communication fails even though the MNT port of controller 0 (CM#0) and
the LAN port of the PC are connected, check that Master LED of controller
0 (CM#0) is lit. If the Master LED of controller 1 (CM#1) is lit for dual
controller model, use the MNT port of controller 1 (CM#1).
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
Copyright 2011 FUJITSU LIMITED
140
End of procedure