NEC Express5800 320La User Manual page 170

Hide thumbs Also See for Express5800 320La:
Table of Contents

Advertisement

Status Lamp
Error Message
Color State
CPU1 +5.0vsAlm00
Amber Blink
CPU1 +5.0vsAlm02
Amber Lit
CPU1 +5.0vsAlm07
Amber Blink
CPU1 +5.0vsAlm09
Amber Lit
CPU1 Broken
Green
CPU1 FAN Alm 01
Amber Blink
CPU1 FAN Alm 02
Amber Blink
CPU FANvltAlm00
Amber Blink
CPU FANvltAlm02
Amber Lit
CPU FANvltAlm07
Amber Blink
CPU FANvltAlm09
Amber Lit
CPU1 Missing
Green
CPU1 offline
Green
CPU1 removed
Green
CPU1 Temp Alm 00
Amber Blink
CPU1 Temp Alm 02
Amber Lit
CPU1 Temp Alm 07
Amber Blink
CPU1 Temp Alm 09
Amber Lit
CPU11 TempAlm 00
Amber Blink
CPU11 TempAlm 02
Amber Lit
CPU11 TempAlm 07
Amber Blink
5-16 Problem Solving
Table 5-1. LCD Error Messages (continued)
Suspected
Module
CPU module #1
CPU module #1
CPU module #1
CPU module #1
Blink
CPU module #1
CPU module #1
CPU module #1
CPU module #1
CPU module #1
CPU module #1
CPU module #1
Blink
CPU module #1
Blink
CPU module #1
Blink
CPU module #1
CPU module #1
CPU module #1
CPU module #1
CPU module #1
CPU module #1
CPU module #1
CPU module #1
Description
5-V power voltage alarm (lower limit)
Fatal 5-V power voltage alarm (lower
limit)
5-V power voltage alarm (upper
limit)
Fatal 5-V power voltage alarm
(upper limit)
CPU module failure
Cooling fan 1 alarm
Cooling fan 2 alarm
Voltage alarm (lower limit) of the
CPU module cooling fan
Fatal voltage alarm (lower limit) of
the CPU module cooling fan
Voltage alarm (upper limit) of the
CPU module cooling fan
Fatal voltage alarm (upper limit) of
the CPU module cooling fan
CPU not found
The CPU module has been logically
disconnected.
The CPU module has come off.
Temperature alarm (lower limit)
Fatal temperature alarm (lower limit)
Temperature alarm (upper limit)
Fatal temperature alarm (upper limit)
CPU#1 temperature alarm (lower
limit)
Fatal CPU#1 temperature alarm
(lower limit)
CPU#1 temperature alarm (upper
limit)
Action
Contact your service
representative.
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
Contact your service
representative.
Activate the ft server utility, or
remove the module and then
mount it again. If the same
error message is still
displayed, contact your
service representative.
Check the module for a
removed screw, or remove the
module and then mount it
again. If the same error
message is still displayed,
contact your service
representative.
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.