Chapter 4
Connecting Cables
4.4
Power Cord Connection
(2)
Fasten the plug of the power cord with the release tie.
Wrap the release tie around the power cord and fasten the release tie from either side. Make sure
that the release tie is not loose.
2
Connect the power cords to the socket.
Connect the plug at the other end of each power cord to the socket.
Connecting two or four power cords for each enclosure to different two power supply facilities im-
proves the availability of the power supply facilities against failures.
4.4.2
When 1U Power Distribution Unit is Installed (for Regions Other than EMEA&I)
The following procedure explains how to connect the power cord when a 1U power distribution unit is instal-
led.
To help with power cord management and prevent incorrect connections, attach labels to the power cords
and make a note of connection origins and destinations.
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Configuration Guide (Basic)
Do Not
Do not use the server service outlet to connect a power cord for the ETERNUS
DX Disk storage system.