• Do not run the cable near a high frequency generating device.
• Use cable protectors in case the cables are run on the floor.
• Aerial distribution wiring is not allowed.
• Trunks must be installed with lightning protectors.
• Do not install the DSX Terminal in the SL1100 system, it does not work properly.
1.6.3 Trunk Cabling
Trunk cabling is required for the 4COIDB or 1PRIU PCBs.
Refer to
INSTALLING THE EXPANSION INTERFACE CARDS on page 2-38
4COIDB and 1PRIU PCBs.
1.6.4 Extension Cabling
The 084M-B1 PCB within each KSU provides two "RJ61" modular jacks for digital extension (8ports)
and one for analog extensions (4ports).
Before plugging in the Multiline Telephone, DSS Console, Single line Telephone
or Doorphone, ensure all Main and Expansion KSUs are powered off.
DSX Terminal does not work properly when it connected.
T: Tip
R: Ring
Multiline Telephone
2-14
J103 J431 J411
J102 J101
ESI 5-8 ESI 1-4
5
4 3
6 2
7 1
Port 1 Port 2 Port 3 Port 4
T
R
T
Modular Cable
(2-wire, Straight)
Exit
Help
ABC
DEF
Flash
Transfer
1
2
3
GHI
JKL
MNO
Mute
DND
4
5
6
PQRS
TUV
WXYZ
Clear/Back
7
8
9
0
Speaker
Hold
DSS Console
Figure 2-21 Digital Extension Cabling
for mounting and cabling
J421
J7
8
R
Max cable length
24AWG ( 0.5 mm)
MLT, DSS
ISSUE 1.0
300 m
(984.3 ft)
Installation