Door Box Basic Setup - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

ISSUE 1.0
Program 32 : Door Box and Sensor Setup
Level
IN
Description
Use Program 32-03 : Door Box Basic Setup to select the chime pattern and gain level for each Door
Box. There are six distinctive chime patterns. The chime tones are defined in
Setup. on page 2-419
The Door Box feature is called Door Phone when programming via WebPro and using a multiline terminal.
Input Data
Door Box Number
Item No.
01
Chime Pattern
02
CODEC Transmit Gain Setup
(System to Door Box)
03
CODEC Receive Gain Setup
(Door Box to System)
Conditions
None
Feature Cross Reference
• Door Box
Programming Manual

32-03 : Door Box Basic Setup

Item
7 = Door Box Ring 7 (SL1000)
8 = Door Box Ring 8 (SL1000)
1 ~ 63 (- 15.5 dB ~ + 15.5 dB)
1 ~ 63 (- 15.5 dB ~ + 15.5 dB)
80-01 : Service Tone
1 ~ 8 (SL1000)
1 ~ 6 (SL1100)
Input Data
0 = None
Door Box 1 = 1
1 = Door Box Ring 1
Door Box 2 = 2
2 = Door Box Ring 2
Door Box 3 = 3
3 = Door Box Ring 3
Door Box 4 = 4
4 = Door Box Ring 4
Door Box 5 = 5
5 = Door Box Ring 5
Door Box 6 = 6
6 = Door Box Ring 6
Door Box 7 = 1 (SL1000)
Door Box 8 = 1 (SL1000)
SL1000/SL1100
Program
32
Default
32 (0 dB)
32 (0 dB)
2-329

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl1100

Table of Contents